It seems to be coming from the wet side of the pump the strainer housing. If thats not the issue, is the pump sized correctly for the filter, and not under/over sized? Finally, if the new superpump is larger than the old one, the amperage draw may be too much for the breaker. But lack of sand should not cause a leaking problem. but the digital display panel wont light up, does the propane need to be connected and turned on to make the display panel work?? Is this a ground issue or something else? If the voltage between the orange and black is not 12VAC, you need to replace the rectifier or the board. Pat. I have an inground salt water pool with a spa and my flow rate was low so I cleaned out everything and replaced the filters and now the flow rate seems good with one problem. Juat replaced motor. There are ants around the AutoChlor, the lights come on but which is the problem, the pump or the switching system? Id call the install tech for troubleshooting. God bless your heart! The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. 3. After connecting the device, the flow led flashes for one minute and turns off. A jammed impeller or blown capacitor can lead to a tripped breaker. The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. What does your water temp say? Hi Rachel, Im guessing a Hayward Perflex DE filter? But just like any sort of equipment, even the most well-made products sometimes need repairs. Its a little over 3 years old and the cell checked out fine. Going to try 2 hrs low and 6 high. Thank you! Hi Brian, is this a DE filter? Could possibly be loose wires on the motor or timer, possibly a loose centrifugal switch or stationary switch on the motor, or maybe the windings in the motor are shorting out. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Other timers will have a different switch, but all should have someway to override. I noticed the pump wasnt running this week and saw the LED display was off and had moisture in it. Thank you. I let it cooled down tho the temp was only 90 at that time. "width": "611",
I have a Hayward pro series filter and Hayward pump. Hi I have a variable speed ecostar and am now having the drive error, drive stalled. The arrow should point in the same direction as the water flow. In cases such as this, it is often wise to get things going sooner, and replace the pump (or motor) now, and sort out the money later unless you are able to cover the pool with a winter cover, to block the sun, or load up the pool with lots and lots of chlorine and daily brushing/skimming both of which could sustain the water for up to 2 weeks, in most cases. Hi, that could be many things, from low water level to a broken impeller, but its usually an air leak. The cell amperage is above the maximum limit. 6. If you wire 110V to a 220V motor, it will not usually run, or will only slowly turn. It's a little over 3 years old and the cell checked out fine. The centrifugal switch may be loose, or the stationary switch may be bent and not releasing. Hi, each pool filter system has a different pressure, but if there was a normal pressure, many systems are designed to run around 10 psi (clean). Had the filter for 3 years. 3200 ppm is the ideal level. Check wires on the other end, where they connect to the autochlor too. There are some pumps that will draw air in thru a faulty shaft seal, which will leak water, dripping below the pump, when the pump shuts off. The main filters and baskets are well maintained. Hi Kevin, I think I would check the capacitor(s), maybe replace them if they test weak, or look cracked or damaged. Check all the wire connections inside the motor on the terminal board, the 2 wires and the ground wire. the , . My question to you is what to do from here. 24V after the transformer is present. Our troubleshooting guide will help you get it up and running in no time. Click OK to extend your time for an additional 0 minutes. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. Pump motors are continuous duty, meaning that they are meant for continuous operation, it wont harm the motor, or cause it to overheat. Yes, kind of does defeat the purpose, but you may not need to heat the pool all the time, so can still run on low-speed for many hours per day. Start here Step 1: Select your pool type. Guess it is time for a new drive. I opened my pool this weekend and started the pump and let it run for few hours before stopping it. When I finally turned it off again it would not come back on. When it cools it automatically trys to start again and motor turns on after 3 seconds of humming. I have chalked all the connections and lubricated the basket seal. The Intermatic T106M timeclock is the standard outdoor timeclock, then you can set it to run 12 hrs daily +/-, or as needed. One washer on each side of the spring, you are correct. Outlet works fine. "name": "In The Swim",
Then sometimes with no rhyme or reason the pump shuts down and will not come back on until after I turn off and on all breakers. Or you may have an Air Leak in front of the pump, on the pump lid or the pipe coming into the pump usually. I tried to snake the pump but didnt find anything. Could also be a loose wire connection, the power wires. Most Common areas include the pump lid (must be very tight, with lubed lid o-ring), and the threaded pipe that comes into the FRONT of the pump (must be very tight and sealed if loose, use Pool Putty to fix, or replace the fitting) the effluent or exit pipe fitting leaking will not draw air, that is on the pressure side not the suction side. If the capacitor is bulged or cracked, or looks like it is burned or charred, you can assume that it is D.O.A. I recently noticed what appears to be a shaft seal leak. Anything I can do on my own to fix this? Most pump breakers are not GFI, it might not trip if it is a regular non-GFI. of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the dr myers ultrasound. Most heaters can operate on 120V/240V, either one. Not sure what would cause that?!? Anything else to fiddle with or bad motor? I have an older Hayward Pool pump for an above ground pool. (GFI 240V 20amp) Thanks for your insight. In particular, if the salt content of your pool water is too high, your metal screws, handrails, ladders, and covers will rust excessively. The price seems steep ($500+ for the pump) and it seems only Leslies carries them. Check that the motor wiring matches input voltage, if the motor can be wired 110/220V. I have to say Ive never touched it before during almost 6-years of normal operation. Good luck! So, if you replaced the handle assembly and valve, aka the Key Assy, item SPX0714BA, and water is still coming out of the backwash line? Good luck! Getting air in basket, changed gasket with lube still have the same issue. I have the intermatic digital two speed timer. Its never happened before. I purchased a hayward powerflo matrix 1.5 pump and Proseries 21 Filter a week and a half ago. Does the LED light turn off after 60 seconds? If it makes no noise at all, check that the GFCI test button is not tripped, and flip the circuit breaker off and back on. 3 possible solutions. It looks like its coming from in between the motor and pump.Am I correct in thinking I need a new seal plate kit? And you cant rule out a problem with the circuit board either. The salt cylinder is clean. The filter timer will not turn on at all, even when trying manually but the cleaner does. New Assy is $500. The cord does feel warm to the touch. Maintenance. Any suggestions welcome. Sun was beating on it. Hi Jim, check the wire connections, and the voltage coming into the motor. Is there something I forgot to do? Do you know what the suggested torque is for the housing cap screws? For the clamp band, yes the washer with the slightly smaller hole I.D. External bypass is out of adjustment. I have a 2 year old Hayward Pump 1 HP wired for 110 with 20 Amp breaker. I have a Hayward pump with DE filter. https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS the sound may possibly be a problem with the internal bypass, located in the front header. Second thought is are the pipes plumbed into the valve correct? I first thought it might be the motor capacitor, new cap, problem still the same. No lights are coming on as if no power. The loose wire you found in the pump, that was a good catch, there should be no hanging wires in the rear of the motor, all wires from the terminal board, to the switches and capacitor should be tightly connected, and the metals ends should never touch any other metal parts, except the terminal they connect to Retrace your steps to recheck power to the motor. Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. It seems to only operate in the highest speed. "keywords": "",
It is a H400FDN series. I dont see any leaks n pressure seems little bit higher than normal. At that moment the generation led turns on and turns off after a few seconds. Second possibility is the pump is too high above water level. Could be one of these. Holes in grids, or stitching coming apart But most likely an air leak, either before or after the pump, pool systems are supposed to be mostly air tight, though most are not completely. Hayward Pool Heater Troubleshooting - In The Swim Pool Blog Hi Donna, the screws that are removed to rotate are the long thru-bolts that run thru the motor, and are turned at the rear of the motor (spray with WD-40 first). In the meantime, could you send me a link for the capacitor that I need? The click I was speaking of is definitely in the motor, not the outlet, although I realize they are right next to each other. It is a Hayward Super Pump 1.5 HP (model #SP2610X15). Move switch to center position and adjust dial to a percentage that you think it needs. It could also be a loose switch in the back of the motor. What am I not doing? are red velvet ants dangerous to dogs stone county, mississippi mugshots disney half marathon 2023 crooked house (2008 trailer) Also check that the stationary switch (6 oclock) and the centrifugal switch (dead center) are not loose or misaligned. If all good, check the capacitor, at 9 oclock, looking for bulging or cracking or burned marks. Inspect the area where the wires connect to the motor, aside from that Im stumped havent had the chance yet to work on too many VS motors. Third, check the back of the motor, the centrifugal switch on the end of the shaft and the stationary switch at 6 oclock to be sure they are tight and aligned tab to tab, and not loose or misaligned. It makes humming sound 1-2 times before starting. Similar pumps, with the same flow rate characteristics, are not less expensive. To determine the cause of your noisy pump, investigate the following reasons: Theres no need to feel overwhelmed if your Hayward pool pump isnt functioning correctly. If that all checks out, be sure that there are no air leaks on the suction side of the impeller, around the lid, drain plugs or pipe coming into pump. What do you think is the problem? Harwil type flow switches can become damaged over time and will need replacement at some point. Repair or replace any tripped breakers or blown fuses. Weve tried everything. I believe we have the drawing in air issue at filter, I cannot locate to purchase the o ring seal and valve cover for this model. Pump motors are not normally on a GFCI breaker, unless your pump plugs in to an outlet. Hose them off well, and then soak them in a DE filter cleaner, in a 5 gallon bucket. Is the shaft spinning freely? Thank you very much!! New gauge was ordered. What do I need to replace the seal plate, the diffuser, the pump housing? If youre correct that theres a problem with the internal bypass, what should I do? Nothing tripped. Is that a result of all the water that got in the equipment during the storm? Flip the switch opposite, and you should be all set. Hi thanks for speedy reply the breaker is 20 amp with a GFCI. I removed it and put the old pump back (20 years old), it works and does not shut down. One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. The hub was leaking and had to be replaced. A local electric motor shop should have them, or easy to find online. Thanks. Pool360 - Blue-essence-20 20k Gal Salt Chlorination System - Poolcorp The AquaTrol is an above ground pool salt chlorine generator that can chlorinate a pool up to 18,000 gallons. I do not see any water leaks around the pump or the filter other than a few drops under the chlorinator. Check the shaft for free spinning movement, and check the capacitor for signs of failure (bulges, cracks, smoke). Water temperature is above 140 degrees F. Make sure that either 120VAC or 240VAC input power is connected to the proper screw terminals at the Aqua Rite control. Pump flow rates are found on pump flow rate curves. Thank you very much in advance. hayward super pump C48L2N134B1. The Aquatrol kind of jumped and the breaker tripped. I have a dual flow 2 speed pump. I would call back the electrician, he may have fumbled this while wiring it, such a problem is rare, and could hardly be blamed on the manufacturer, but if your electrician says that its not his fault, have him put in writing on company letterhead, what the defect of the motor is which can help you in getting warranty assistance. It could also be due to the air intake, or the filter pressure, Water around the base, check the motor bolts or seal plate clamp for tightness on the seal plate o-ring, and check drain plugs for tightness, but most likely its coming from around the outlet pipe, and dripping down to the base, or from the shaft seal, which leaks directly mid bottom, where motor connects. "@type": "BlogPosting",
"dateModified": "2/24/2015",
If the shaft is free turning, but the pump does not turn on, check power connections. Can I replace this pump housing or do I need a new pump? It could also be something loose inside of the tank. "primaryImageOfPage": {
This year, I noticed at times that the flow rate on low speed is less than it was last year. http://www.inyopools.com/blogSHOP at our online store! "datePublished": "2/24/2015",
Timer 1 comes on at 10:30 at 1450rpms and runs to 3:30. There must be a leak. Could be a problem with the centrifugal switch, located dead center on the rear of the motor, or the stationary switch, located beneath it, and contacting each other in the center. Now when my sweeper comes on my waterfall feature from my spa does not turn off like it should and my sweeper moves slowly and in circles. The impeller does not need to be spun on too tight, the spin direction of the shaft will keep it snug, so just hand tight. Be sure that bare wires are not touching other bare wires or terminals, or other metals. Normally they last longer. Checked everything still doesnt work . Also make sure that the stationary switch copper tabs are not fused together, and that it is centered on the centrifugal switch. If the bolts do not tighten fully, it could be that the housing threaded receivers are loose and spinning as you try to tighten the bolts. Or buy a new motor. Terrible storms 2 nights ago. Regardless, after wiring it up (we did the hot on the bottom and neutral on the top), I put water in the basket and turned on the pump. Put it in the line at the pool, and as the pump begins to catch prime, crimp the hose and slowly pull out of the pipe. Could be clogged impeller? What are the amp and volt readings for the new cell? Checked pump, and appeared that pump had to keep priming . Hi, might have been a small clog in the pipe. The pipe from the pump is connected to the valve in the port labeled PUMP and the pipe returning to the pool connects to the port labeled RETURN. If your shaft IS spinning freely, other causes of a tripped breaker include loose wiring, broken wires, water in the wire conduit, wires inside the motor touching other wires or the metal motor casing, insect infestation in the time clock. Could be a loose lid, or the basket not re-placed properly, and a clogged pump impeller. The motor can be tested briefly without being bolted onto the pump. Any new postings here are unlikely to be seen or responded to by other members. I tried to prime the pump but it still doesnt kick over to cycle anything. You could also use a Hayward 24 sand filter, item E3324. hayward blue essence troubleshooting - Prismatalk.de Look closely at the centrifugal switch on the rear of the shaft, to be sure its tight and is not missing parts (like the springs), engage the switch by hand (power off), to be sure that the stationary switch (located at 6 oclock) is disengaging, or the two copper tabs separate. Any suggestions? Impeller replacement is only ever really needed for breakage or other severe damage, so if it aint broke. Using a circuit tester, I determined that the timer and the inline switch has power. I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. You can, if possible, vacuum to waste by setting the multiport on the Drain to Waste setting, and then vacuuming fast you will discharge silty debris out of the pool. If it still trips the breaker, it may have shorted out the motor windings, and is not repairable. LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. No reset on the pump motor, but a little water on the wiring, and it will pop a GFI outlet. Tripping the breaker, could possibly be a bad breaker, allowing too much voltage to pass thru to the pump. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. I dont know if Im convinced the new pump is bad or not, or if I need higher voltage to the pump. We are snow birds in AZ and want to drain the system for the summer. hayward blue essence troubleshooting . Is this rare? Blower vacuum switch closed when expected open error, If the blower prover switch is closed before blower start-up the control will not start the blower. Checked the circuit breaker and turned it off and on. Thanks. Hi there, 30 psi is pretty high pressure, sounds like the pump is having trouble pushing thru are you using enough DE powder? Reinstalled Same problem recycled power. men's rhinestone dress shoes. Could also be a clogged pump impeller, or a clog in the skimmer line. Hi Anessa, Hayward VS pumps are known to have Drive Errors, whereas Pentair, I dont hear so many problems about the Intelliflo. Hi Dave, check the owners manual to be sure that the cord size used is proper for the motor, and the plug, is a 3-prong grounded plug? Suggestions?
Polk County Sheriff Shooting 68 Times, Articles H